Dento-alveolar rehabilitation with Arcsys implant and Nanosynt bone graft

Authors: Dr. Jéferson Fagundes

Patient gender and age: Female patient, 67 y.o.

Chief complaint: Absence of tooth 12 and aesthetic dissatisfaction

Initial evaluation: After anamnesis, clinical and tomographic examination, a thin alveolar bone structure was observed in the region of element 12 and volume loss of soft tissue, indicating tissue reconstruction associated with implant installation.

Treatment performed

A 3.3×9 Arcsys implant was installed in the region of the element 12, with a torque obtained of 50Ncm. After the implant was installed, a vestibular bone wall fenestration was observed (which was expected, due to the thin bone wall). Soon after, the angular referrer was attached to the implant to personalize the angle of the 3x6x2.5 Arcsys sleeve. After customizing the trunnion to the Arcsys angulator in 6 degrees, the prosthetic component was installed on the implant with the hammer. Then, the autogenous conjunctive graft and the Nanosynt bone graft were applied to the buccal bone wall and protected by an absorbable collagen membrane. The provisional crown was made directly on the multifunctional peek transfer with flow resin. The surgery was completed using PTFE sutures. After 120 days, definitive restorative procedures were initiated, by making ceramic zirconia / feldspathic crowns on teeth and on the implant 12.

Imagem1

FIG. 1 – Initial aspect

Imagem1

FIG. 2 – Initial tomographic section

Imagem1

FIG. 3 – Initial lateral aspect

Imagem1

FIG. 4 – Incisal initial aspect

Imagem1

FIG. 5 – 3,3 x 9 Arcsys implant

Imagem1

FIG. 6 – Implant installed 2mm infra-bone

Imagem1

FIG. 7- Incisal view of the implant

Imagem1

FIG. 8- Angle referrer coupled

Imagem1

FIG. 9- Angulation determined for the abutment

Imagem1

FIG. 10- Angulation customized in 6 degrees

Imagem1

FIG. 11- Abutment installed and Bone graft

Imagem1

FIG. 12- Nanosynt bone graft

Imagem1

FIG. 13- Collagen membrane placed

Imagem1

FIG. 14- Multifunctional transfer over the abutment

Imagem1

FIG. 15- Provisional crown installed

Imagem1

FIG. 16 – Surgery completed

Imagem1

FIG. 17- Lateral postoperative appearance

Imagem1

FIG. 18 – Panoramic image after 30 days

Imagem1

FIG. 19- Clinical aspect after 90 days

Imagem1

FIG. 20- Digital prosthetic planning

Imagem1

FIG. 21- Ceramic crowns on the model

Imagem1

FIG. 22- Cemented crowns: case completed

Imagem1

FIG. 23 – Lateral view: case completed

Imagem1

FIG. 24 – Zoomed image element 12

Imagem1

FIG. 25 – Before/After: lateral view

Imagem1

FIG. 26 – Before/After: frontal view