{"id":511240,"date":"2024-05-08T10:46:17","date_gmt":"2024-05-08T13:46:17","guid":{"rendered":"https:\/\/fgmdentalgroup.com\/blog\/posts\/implante-posterior-con-protesis-en-circonio-cementada-sobre-link\/"},"modified":"2024-05-08T10:46:17","modified_gmt":"2024-05-08T13:46:17","slug":"implante-posterior-con-protesis-en-circonio-cementada-sobre-link","status":"publish","type":"post","link":"https:\/\/fgmdentalgroup.com\/latam\/blog\/posts\/implante-posterior-con-protesis-en-circonio-cementada-sobre-link\/","title":{"rendered":"Implante posterior con Pr\u00f3tesis en circonio cementada sobre link"},"content":{"rendered":"<p><em>Autores: Prof. Dr. Everton Salante e Prof. Dr. Leonardo Piazzetta Pellissari<\/em><\/p>\n<p>PACIENTE DEL SEXO FEMENINO, 40 A\u00d1OS: Alteraciones en el elemento 26 aun despu\u00e9s de retratamiento endod\u00f3ntico.<\/p>\n<p>&nbsp;<\/p>\n<h3>EVALUACI\u00d3N INICIAL<\/h3>\n<p>Paciente present\u00f3 una recidiva de lesi\u00f3n periapical tras el segundo retratamiento<br \/>\nendod\u00f3ntico en el diente 26. La evaluaci\u00f3n cl\u00ednica y radiogr\u00e1fica permiti\u00f3 la constataci\u00f3n de reabsorci\u00f3n radicular con indicaci\u00f3n de exodoncia.<\/p>\n<p>&nbsp;<\/p>\n<h3>TRATAMIENTO EJECUTADO<\/h3>\n<p>Se propuso la sustituci\u00f3n del elemento dental comprometido por un implante inmediato con carga inmediata y confecci\u00f3n de cicatrizador personalizado.<\/p>\n<p>As\u00ed, realizada la exodoncia m\u00ednimamente traum\u00e1tica preservando la arquitectura gingival de la regi\u00f3n, un implante Short de 5&#215;5 mm Arcsys, infraoseo 2 mm, donde \u00e9ste alcanz\u00f3 32 N.cm de estabilidad primaria. De esta forma fue realizada la confecci\u00f3n del cicatrizador personalizado, utilizando un cicatrizador multifuncional de cinta alta y 4 mm de di\u00e1metro personalizado, se a\u00f1adi\u00f3 resina pattern fotoactivada sellando completamente la embocadura del alv\u00e9olo. Previamente a la instalaci\u00f3n del cicatrizador fue realizada la inserci\u00f3n del tapa implante, para evitar que residuos de biomaterial ocuparan el espacio interno del implante, y entonces fue realizado el rellenado del gap con Nanosynt. Enseguida se sac\u00f3 el tapa implante e inmediatamente el cicatrizador personalizado fue cuidadosamente instalado solamente con una presi\u00f3n digital.<\/p>\n<p>Como ventaja de este procedimiento, se puede notar la obliteraci\u00f3n de la embocadura alveolar con concomitante grabado de tejido, iniciando la personalizaci\u00f3n del perfil de emergencia.<\/p>\n<p>Despu\u00e9s de 90 d\u00edas de post operatorio se sac\u00f3 el cicatrizador y la instalaci\u00f3n del pilar con 2,5 mm de transmucoso. Los tejidos peri-implantares ya estaban con el perfil de emergencia satisfactorio para iniciar el escaneado intraoral. El scan body para pilar fue instalado sobre \u00e9ste y los archivos .stl fueron encaminados para el laboratorio prot\u00e9sico, el cual confeccion\u00f3 una corona en circonio sobre link met\u00e1lico para ofrecer mayor resistencia y evitar la ocurrencia de rotura de la corona instalada directamente sobre el componente prot\u00e9sico. La corona fue cementada al link utilizando cemento Allcem Core.<\/p>\n<p>Fue realizado un acabado en la regi\u00f3n de interfaz del link con la corona prot\u00e9sica y el conjunto fue instalado sobre el pilar con torque de 10 N.cm. Sobre el tornillo fue inserida cinta tefl\u00f3n y resina Vittra APS Unique.<\/p>\n<p>&nbsp;<\/p>\n<h3>PASO A PASO<\/h3>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-500312\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1IMG_8825-01.jpeg\" alt=\"01 - Situa\u00e7\u00e3o inicial.\" width=\"1080\" height=\"867\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1IMG_8825-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1IMG_8825-01-300x241.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>01 &#8211; Situaci\u00f3n inicial.<\/p>\n<p><img decoding=\"async\" class=\"size-full wp-image-500327\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/2IMG_8826-01.jpeg\" alt=\"02 - Alv\u00e9olo ap\u00f3s a exodontia.\" width=\"1080\" height=\"868\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/2IMG_8826-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/2IMG_8826-01-300x241.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>02 &#8211; Alv\u00e9olo tras la exodoncia.<\/p>\n<p><img decoding=\"async\" class=\"size-full wp-image-500341\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/3IMG_8834-01.jpeg\" alt=\"03 - Instala\u00e7\u00e3o de implante short. \" width=\"1080\" height=\"863\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/3IMG_8834-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/3IMG_8834-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>03 &#8211; | Instalaci\u00f3n de implante short.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500355\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/5IMG_8836-01.jpeg\" alt=\"04 - Cicactrizador multifuncional personalizado.\" width=\"1080\" height=\"864\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/5IMG_8836-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/5IMG_8836-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>04 &#8211; Cicactrizador multifuncional personalizado.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500369\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/6IMG_8835-01.jpeg\" alt=\"05 - Preenchimento do gap com Nanosynt.\" width=\"1080\" height=\"864\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/6IMG_8835-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/6IMG_8835-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>05 &#8211; Rellenado del gap con Nanosynt.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500383\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/7IMG_8837-01.jpeg\" alt=\"06 - Instala\u00e7\u00e3o do cicatrizador personalizado com Vittra APS. \" width=\"1080\" height=\"864\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/7IMG_8837-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/7IMG_8837-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>06 &#8211; Instalaci\u00f3n del cicatrizador personalizado con Vittra APS.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500397\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/8IMG_9153-01.jpeg\" alt=\"07 - P\u00f3s operat\u00f3rio de 7 dias. \" width=\"1080\" height=\"864\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/8IMG_9153-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/8IMG_9153-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>07 &#8211; Post operatorio de 7 d\u00edas.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500411\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/9IMG_9154-01.jpeg\" alt=\"08 - Aspecto gengival ap\u00f3s tr\u00eas meses.\" width=\"1080\" height=\"865\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/9IMG_9154-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/9IMG_9154-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>08 &#8211; Aspecto gingival tras tres meses.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500425\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1000194000-02.jpeg\" alt=\"09 - Link met\u00e1lico sobre componente prot\u00e9tico.\" width=\"1080\" height=\"720\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1000194000-02.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1000194000-02-300x200.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>09 &#8211; Link met\u00e1lico sobre componente prot\u00e9sico.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500467\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/141000181394-02.jpeg\" alt=\"10 - Cimento na parte interna da coroa. \" width=\"1080\" height=\"866\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/141000181394-02.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/141000181394-02-300x241.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>10 &#8211; Cemento en la parte interna de la corona.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500481\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/171000181392-01.jpeg\" alt=\"11 - Coroa em posi\u00e7\u00e3o no modelo impresso.\" width=\"1080\" height=\"864\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/171000181392-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/171000181392-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>11 &#8211; Corona en posici\u00f3n en el modelo imprimido.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500495\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/191000181387-01.jpeg\" alt=\"12 - Situa\u00e7\u00e3o fi nal antes da aplica\u00e7\u00e3o da resina.\" width=\"1080\" height=\"865\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/191000181387-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/191000181387-01-300x240.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<p>12 &#8211; Situaci\u00f3n final antes de la aplicaci\u00f3n de la resina.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500439\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/2110176528-01.jpeg\" alt=\"13 - Aspecto radiogr\u00e1fico final.\" width=\"718\" height=\"1080\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/2110176528-01.jpeg 718w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/2110176528-01-199x300.jpeg 199w\" sizes=\"(max-width: 718px) 100vw, 718px\" \/><\/p>\n<p>13 &#8211; Aspecto radiogr\u00e1fico final.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-500312\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1IMG_8825-01.jpeg\" alt=\"01 - Situa\u00e7\u00e3o inicial.\" width=\"1080\" height=\"867\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1IMG_8825-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/1IMG_8825-01-300x241.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><\/p>\n<figure id=\"attachment_500519\" aria-describedby=\"caption-attachment-500519\" style=\"width: 1080px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-500509\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/201000181413-01.jpeg\" alt=\"15 - Aspecto final\" width=\"1080\" height=\"866\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/201000181413-01.jpeg 1080w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/201000181413-01-300x241.jpeg 300w\" sizes=\"(max-width: 1080px) 100vw, 1080px\" \/><figcaption id=\"caption-attachment-500519\" class=\"wp-caption-text\">14 e 15 &#8211; Aspecto inicial y final.<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<h3>PRODUCTOS UTILIZADOS<\/h3>\n<p><a href=\"https:\/\/fgmdentalgroup.com\/produtos-implantes\/estojo-cirurgico-e-protetico-arcsys\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-497431\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/04\/estojo-cirurgico-e-protetico.png\" alt=\"\" width=\"250\" height=\"144\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/04\/estojo-cirurgico-e-protetico.png 332w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/04\/estojo-cirurgico-e-protetico-300x173.png 300w\" sizes=\"(max-width: 250px) 100vw, 250px\" \/><\/a> <a href=\"https:\/\/fgmdentalgroup.com\/nanosynt\/\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-444871\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/10\/Caixa_Nanosynt-CE-1.png\" alt=\"\" width=\"200\" height=\"193\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/10\/Caixa_Nanosynt-CE-1.png 1000w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/10\/Caixa_Nanosynt-CE-1-300x290.png 300w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/><\/a><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-472690\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/02\/Cicatrizador-Multifuncional-Cinta-Alta-5mm-05.17.03.png\" alt=\"\" width=\"125\" height=\"222\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/02\/Cicatrizador-Multifuncional-Cinta-Alta-5mm-05.17.03.png 3375w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/02\/Cicatrizador-Multifuncional-Cinta-Alta-5mm-05.17.03-169x300.png 169w\" sizes=\"(max-width: 125px) 100vw, 125px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-465460\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/03\/Implante-6.0x5mm-Short.webp\" alt=\"Implante Arcsys Short\" width=\"200\" height=\"198\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/03\/Implante-6.0x5mm-Short.webp 1024w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/03\/Implante-6.0x5mm-Short-300x297.webp 300w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/03\/Implante-6.0x5mm-Short-150x150.webp 150w\" sizes=\"(max-width: 200px) 100vw, 200px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-451454\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/11\/Mini-Pilar-Angulavel-4x32x25-03.16.png\" alt=\"\" width=\"80\" height=\"183\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/11\/Mini-Pilar-Angulavel-4x32x25-03.16.png 437w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/11\/Mini-Pilar-Angulavel-4x32x25-03.16-131x300.png 131w\" sizes=\"(max-width: 80px) 100vw, 80px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-500530\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/minipilar.png\" alt=\"\" width=\"90\" height=\"206\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/minipilar.png 471w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/minipilar-131x300.png 131w\" sizes=\"(max-width: 90px) 100vw, 90px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-452399\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/11\/Scanbody-1.png\" alt=\"\" width=\"80\" height=\"189\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/11\/Scanbody-1.png 338w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/11\/Scanbody-1-127x300.png 127w\" sizes=\"(max-width: 80px) 100vw, 80px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-500544\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/IS3700_SideView_StandardTip_07122022.png\" alt=\"\" width=\"80\" height=\"263\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/IS3700_SideView_StandardTip_07122022.png 329w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2024\/05\/IS3700_SideView_StandardTip_07122022-91x300.png 91w\" sizes=\"(max-width: 80px) 100vw, 80px\" \/><\/p>\n<p>&nbsp;<\/p>\n<div id=\"gtx-trans\" style=\"position: absolute; left: 523px; top: 433.031px;\">\n<div class=\"gtx-trans-icon\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Autores: Prof. Dr. Everton Salante e Prof. Dr. Leonardo Piazzetta Pellissari PACIENTE DEL SEXO FEMENINO, 40 A\u00d1OS: Alteraciones en el elemento 26 aun despu\u00e9s de retratamiento endod\u00f3ntico. &nbsp; EVALUACI\u00d3N INICIAL Paciente present\u00f3 una recidiva de lesi\u00f3n periapical tras el segundo retratamiento endod\u00f3ntico en el diente 26. La evaluaci\u00f3n cl\u00ednica y radiogr\u00e1fica permiti\u00f3 la constataci\u00f3n de [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":500307,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1497],"tags":[],"produto-relacionado":[1544],"categoria-post":[26],"linha-de-atuacao":[489,478,491],"class_list":["post-511240","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-posts-latam","produto-relacionado-sistema-de-implantes-arcsys","categoria-post-casos-clinicos","linha-de-atuacao-produto-biomateriais-latam","linha-de-atuacao-produto-estetica-latam","linha-de-atuacao-produto-implantes-latam"],"_links":{"self":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/posts\/511240"}],"collection":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/comments?post=511240"}],"version-history":[{"count":0,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/posts\/511240\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/media\/500307"}],"wp:attachment":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/media?parent=511240"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/categories?post=511240"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/tags?post=511240"},{"taxonomy":"produto-relacionado","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/produto-relacionado?post=511240"},{"taxonomy":"categoria-post","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/categoria-post?post=511240"},{"taxonomy":"linha-de-atuacao","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/linha-de-atuacao?post=511240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}