{"id":410653,"date":"2023-05-23T12:01:13","date_gmt":"2023-05-23T15:01:13","guid":{"rendered":"https:\/\/fgmdentalgroup.com\/blog\/\/sellado-bacteriano-en-la-conexion-friccional-del-sistema-de-implantes-arcsys\/"},"modified":"2023-12-15T11:44:19","modified_gmt":"2023-12-15T14:44:19","slug":"sellado-bacteriano-en-la-conexion-friccional-del-sistema-de-implantes-arcsys","status":"publish","type":"post","link":"https:\/\/fgmdentalgroup.com\/latam\/blog\/posts\/sellado-bacteriano-en-la-conexion-friccional-del-sistema-de-implantes-arcsys\/","title":{"rendered":"Sellado bacteriano en la conexi\u00f3n friccional del Sistema de Implantes Arcsys"},"content":{"rendered":"<p><em>Autores: Eng. M.Sc. William de Souza Wiggers e DDS M.Sc Rafael Cury Cecato <\/em><\/p>\n<p>El surgimiento de la implantolog\u00eda, en el inicio del siglo XX, con Payne y Greenfi eld, los precursores de la especialidad, presentaron soluciones como oro y porcelana. Payne describi\u00f3 el implante de una cesta cil\u00edndrica de oro, colocado<br \/>\ntras ensanchamiento del di\u00e1metro del alv\u00e9olo con ayuda de una fresa. Desde all\u00e1, mucha tecnolog\u00eda e innovaci\u00f3n fueron implementadas, muchos productos existentes en el mercado fueron perfeccionados y nuevas t\u00e9cnicas surgieron para contribuir con el alto \u00edndice de \u00e9xito de los implantes end\u00f3seos.<\/p>\n<p>La literatura de la implantolog\u00eda presenta muchas referencias cient\u00edficas que comprueban la efi ciencia de las soluciones de esta \u00e1rea y uno de los destaques queda a cargo de la conexi\u00f3n c\u00f3nica friccional, que present\u00f3 a la Odontolog\u00eda nuevas posibilidades de planeamiento y ejecuci\u00f3n, lo que les trajo a los profesionales de la implantolog\u00eda la capacidad de entregar mejores resultados en est\u00e9tica, funci\u00f3n y salud peri-implantar, con m\u00e1s efi ciencia en la rehabilitaci\u00f3n sobre implantes dentarios.<\/p>\n<blockquote><p>&#8220;El exclusivo Sistema de Implantes Arcsys confirma la evoluci\u00f3n de la marca FGM, anticipando las necesidades de mercado con todas sus posibilidades de angulaci\u00f3n. La l\u00ednea posee la certifi caci\u00f3n CE, sello que confi rma la calidad de los productos de acuerdo con la reglamentaci\u00f3n de la Comunidad Europea y los diferenciales quedan a cargo de la reducci\u00f3n expresiva del volumen de componentes en stock, planeamientos m\u00e1s refinados, con mayor previsibilidad en los resultados, siendo uno de los destaques el sellado bacteriano presente en la conexi\u00f3n de este sistema.&#8221; Rafael Cury Cecato &#8211; Consultor cient\u00edfico senior (Biomateriales).<\/p><\/blockquote>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone wp-image-410636\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Tabela_Prancheta-1-300x139.png\" alt=\"\" width=\"483\" height=\"224\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Tabela_Prancheta-1-300x139.png 300w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Tabela_Prancheta-1.png 933w\" sizes=\"(max-width: 483px) 100vw, 483px\" \/><\/p>\n<p>Frecuencias absolutas y relativas de medios con crecimiento bacteriano, tras 48 h, en diferentes angulaciones de componentes prot\u00e9sicos, ciclados y no ciclados\u2075.<\/p>\n<h3><strong>LA LITERATURA DEMUESTRA QUE CONEXIONES C\u00d3NICAS INTERNAS SON M\u00c1S EFICIENTES EN LA DISIPACI\u00d3N DE LAS FUERZAS GENERADAS EN LA INTERFAZ ENTRE IMPLANTE Y COMPONENTE, BIEN COMO EN LA ESTABILIDAD DEL ABUTMENT PROT\u00c9SICO\u00b9\u207b\u2074.<\/strong><\/h3>\n<p>En estudio realizado por el equipo de investigadores asociados a la Prof. Dra. Elizabeth Martinez5, de la Facultad Sao Leopoldo Mandic, evaluando justamente el sellado microbiol\u00f3gico en los implantes friccionales Arcsys, fue comprobada<br \/>\nsu efi cacia en 100% de las muestras (Tabla 1)\u2075. Tales resultados fueron confi rmados tanto en las condiciones cicladas como no cicladas, para los grupos con componentes prot\u00e9sicos rectos y con 5, 10 y 20 grados, acreditando la efi ciencia del sistema Arcsys en diversas condiciones cl\u00ednicas.<\/p>\n<p>Debido al diferencial de personalizaci\u00f3n de la angulaci\u00f3n de los componentes<br \/>\nprot\u00e9sicos en hasta 20 grados, es posible optimizar la relaci\u00f3n entre el posicionamiento del implante y de la pr\u00f3tesis dental, sin comprometer las caracter\u00edsticas funcionales del componente. Esta angulaci\u00f3n es viabilizada por el uso de una liga de acero inoxidable, perfectamente viable biol\u00f3gicamente\u2076, en la fabricaci\u00f3n del componente prot\u00e9sico, asociado al uso de un dispositivo, haciendo posible el ajuste angular del componente<\/p>\n<p><img decoding=\"async\" class=\"alignnone wp-image-410526\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/MicrosoftTeams-image-122-289x300.png\" alt=\"\" width=\"429\" height=\"445\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/MicrosoftTeams-image-122-289x300.png 289w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/MicrosoftTeams-image-122.png 724w\" sizes=\"(max-width: 429px) 100vw, 429px\" \/> \u00a0<img decoding=\"async\" class=\"alignnone wp-image-410540\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/MicrosoftTeams-image-140x300.png\" alt=\"\" width=\"206\" height=\"441\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/MicrosoftTeams-image-140x300.png 140w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/MicrosoftTeams-image.png 1006w\" sizes=\"(max-width: 206px) 100vw, 206px\" \/><\/p>\n<p>1.1 e 1.2 | Im\u00e1genes de la secci\u00f3n transversal y longitudinal de la conexi\u00f3n entre implante y componente friccional Arcsys, capturadas por microCT, demostrando la ausencia de GAPs en la conexi\u00f3n.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-410484\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-05-anosE1-300x158.jpg\" alt=\"\" width=\"427\" height=\"225\" title=\"\"> \u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-410498\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-05-anosE2-300x210.jpg\" alt=\"\" width=\"323\" height=\"226\" title=\"\"><\/p>\n<p>2.1 e 2.2 | Aspectos cl\u00ednico y radiogr\u00e1fico de los tejidos peri-implantares con 5 a\u00f1os de funci\u00f3<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-410512\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-04-anos_J1-178x300.jpg\" alt=\"\" width=\"255\" height=\"430\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-04-anos_J1-178x300.jpg 178w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-04-anos_J1-scaled.jpg 1522w\" sizes=\"(max-width: 255px) 100vw, 255px\" \/> \u00a0<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-410470\" src=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-04-anos_J2-125x300.jpg\" alt=\"\" width=\"179\" height=\"429\" title=\"\" srcset=\"https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-04-anos_J2-125x300.jpg 125w, https:\/\/fgmdentalgroup.com\/wp-content\/uploads\/2023\/05\/Acompanhamento-04-anos_J2-scaled.jpg 1071w\" sizes=\"(max-width: 179px) 100vw, 179px\" \/><\/p>\n<p>3.1 e 3.2 | Aspectos cl\u00ednico y radiogr\u00e1fico de los tejidos peri-implantares con 4 a\u00f1os de funci\u00f3n<\/p>\n<p>En el estudio referenciado anteriormente, el comprobado sellado bacteriano de la conexi\u00f3n friccional del Sistema de Implantes Arcsys, soluciona posibles complicaciones futuras relacionadas a la percolaci\u00f3n bacteriana en la interfaz implante\/componente, quitando una posible e importante causa del desarrollo<br \/>\nde enfermedades peri-implantares.<\/p>\n<p>Esta adaptaci\u00f3n es ratificada al analizar que la conexi\u00f3n friccional promueve una \u201csoldadura fr\u00eda\u201d entre componente prot\u00e9sico e implante, evidenciadas en las im\u00e1genes de microscopia electr\u00f3nica de barredura5,7, evitando as\u00ed la formaci\u00f3n de espacios en la interfaz del conjunto, promoviendo el sellado y evitando la colonizaci\u00f3n bacteriana de la regi\u00f3n. Este sellado microbiol\u00f3gico efectivo, proporciona resultados biol\u00f3gicos, funcionales y est\u00e9ticos superiores a los encontrados en los dem\u00e1s sistemas disponibles del mercado.<\/p>\n<h3>REFERENCIAS BIBLIOGR\u00c1FICAS<\/h3>\n<p>1. Koutouzis T, Wallet S, Calderon N, Lundgren T. Bacterial Colonization of the Implant\u2013Abutment Interface Using an In Vitro Dynamic Loading Model. J Periodontol 2011; 82: 613\u2013618.<\/p>\n<p>2 Alves DCC, de Carvalho PSP, Elias CN, Vedovatto E, Martinez EF. In vitro analysis of the microbiological sealing of tapered implants after mechanical cycling. Clin Oral Investig 2016; 20: 2437\u20132445.<\/p>\n<p>3 Alves DCC, de Carvalho PSP, Martinez EF. In vitro microbiological analysis of bacterial seal at the implant-abutment interface using two morse taper implant models. Braz Dent J 2014; 25: 48\u201353.<\/p>\n<p>4 Bozkaya D, M\u00fcft\u00fc S. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants. J Biomech 2005; 38: 87\u201397.<\/p>\n<p>5 de Aguiar Vilela J\u00fanior R, Cl\u00e1udio Aranha L, Nelson Elias C, Ferreira Martinez E. In vitro analysis of prosthetic abutment and angulable frictional implant interface adaptation: mechanical and microbiological study. J Biomech 2021; 128: 110733.<\/p>\n<p>6 Cecato RC, Martinez EF, Benfatti CAM. Analysis of the Viability and Morphology of Gingival Cells on Materials Used in Novel Prosthetic Components: In Vitro Study. J Contemp Dent Pract 2022; 23: 22\u201330.<\/p>\n<p>7 Costa MB, Ferreira LFACM, Takeshita WM, Trento CL. Scanning electron microscopic evaluation of microgap size in Morse tarer with straight and angled abutments. Gen Dent 2022; 70: 34\u201339.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Autores: Eng. M.Sc. William de Souza Wiggers e DDS M.Sc Rafael Cury Cecato El surgimiento de la implantolog\u00eda, en el inicio del siglo XX, con Payne y Greenfi eld, los precursores de la especialidad, presentaron soluciones como oro y porcelana. Payne describi\u00f3 el implante de una cesta cil\u00edndrica de oro, colocado tras ensanchamiento del di\u00e1metro [&hellip;]<\/p>\n","protected":false},"author":18,"featured_media":410628,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1178,1497],"tags":[1270],"produto-relacionado":[1544],"categoria-post":[],"linha-de-atuacao":[491],"class_list":["post-410653","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-post","category-posts-latam","tag-implantes-latam","produto-relacionado-sistema-de-implantes-arcsys","linha-de-atuacao-produto-implantes-latam"],"_links":{"self":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/posts\/410653"}],"collection":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/comments?post=410653"}],"version-history":[{"count":0,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/posts\/410653\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/media\/410628"}],"wp:attachment":[{"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/media?parent=410653"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/categories?post=410653"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/tags?post=410653"},{"taxonomy":"produto-relacionado","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/produto-relacionado?post=410653"},{"taxonomy":"categoria-post","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/categoria-post?post=410653"},{"taxonomy":"linha-de-atuacao","embeddable":true,"href":"https:\/\/fgmdentalgroup.com\/latam\/wp-json\/wp\/v2\/linha-de-atuacao?post=410653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}